BXRZV - MOUSE KLEEN KIT/OFFICE DUSTER II JR, TX274

  • MSDS: BXRZV
  • Manufacturer: TEXWIPE CO
  • Product Name: MOUSE KLEEN KIT/OFFICE DUSTER II JR, TX274
  • National Stock Number: 7045-01-373-0025
Product Identification

Product ID:MOUSE KLEEN KIT/OFFICE DUSTER II JR, TX274
MSDS Date:03/01/1993
FSC:7045
NIIN:01-373-0025
MSDS Number: BXRZV

Responsible Party
TEXWIPE CO
650 EAST CRESCENT AVE
UPPER SADDLER RIVER, NJ 07458
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 201-327-9100

Preparer: SCOTT FAHY

Cage: 21994

Contractor
TEXWIPE CO
308 UPPER SADDLE RIVER, NJ 07458-1827 US

Telephone: 201-327-5577

Cage: 21994

Ingredients

METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 100%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


(V/V). ING 1 WAS MUTAGENIC IN BACTERIAL CELL

RTECS: 9999999ZZ


IN WHOLE ANIMAL ASSAYS. SLIGHT, BUT SIGNIFICANT,

RTECS: 9999999ZZ


FETAL WEIGHTS) HAS BEEN OBSERVED IN OFFSPRING OF RATS

RTECS: 9999999ZZ


WHICH IS ALSO MATERNALLY TOX; NOT EFTS ON

RTECS: 9999999ZZ


STUDIES IN RABBITS @ 50,000, 1000 & 100 PPM ING 1

RTECS: 9999999ZZ


PERFORMANCE HAVE NOT BEEN CONDUCTED, HOWEVER, LIMITED

RTECS: 9999999ZZ


NOT INDICATE ADVERSE EFTS ON FEMALE REPRO PERFORMANCE

RTECS: 9999999ZZ


OVEREXP TO VAPS BY INHAL MAY INCUDE TEMPORARY NERV

RTECS: 9999999ZZ


CONFUSION, INCOORD, & LOSS OF CONSCIOUSNESS. HIGHER

RTECS: 9999999ZZ


HEART'S ELEC ACTIVITY W/IRREG PULSE,

RTECS: 9999999ZZ


CONT W/LIQ MAY CAUSE FROSTBITE. CHLOROFLUOROCARBON

RTECS: 9999999ZZ


EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT

RTECS: 9999999ZZ


CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN

RTECS: 9999999ZZ


ONLY IN SITUATIONS OF EMERGENCY LIFE

RTECS: 9999999ZZ


IN LOW PLACES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH CONCS OF VAP IS HARMFUL
& MAY CAUSE HEART IRREGULARITIES, UNCON/DEATH. INTENTIONAL MISUSE
CAN BE FATAL. VAP REDUCES OXYG AVAIL FOR BRTHG & IS HVR/AIR. LIQ
CONT CAN CAUSE FROSTBITE. CMPD IS UNTEST FOR SKIN/EYE IRRIT, & IS
UNTESTED FOR ANIMAL SENSIT. TOX DESCRIBED IN ANIMALS EXPOSED BY
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:INHAL TO CONCS RANGING FROM 5% TO 70%
INCLUDES EFTS ON CNS, LIVER, LUNGS, KIDNEYS, SPLEEN; CARDIAC
SENSIT; DECREASED BODY WEIGHT GAIN; & PARTIAL ANESTHESIA. IN
CHRONIC INHAL STUDIES, ING 1 P RDCED SM, BUT STATISTICALLY
SIGNIFICANT, INCREASE OF TUMORS IN MALE RATS, BUT NOT FEMALE
RATS/MALE/FEMALE MICE, (SUPDAT)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEMS MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURE.

First Aid

First Aid:INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/PLENTY OF WATER FOR
@ LST 15 MIN. CALL MD. SKIN:FLUSH W/WATER. TREAT FOR FROSTBITE IF
NEC. INHAL:IMMED REMOVE TO FRESH AIR. KEEP PERSONS CALM. IF NOT BR
THG, GIVE ARTF RESP. IF BRTHG IS DFCLT,GIVE OXYG. CALL MD. NOTE TO
MD:BECAUSE OF POSS DISTURBANCES OF CARDIAC RHYTHM, CATECHOLAMINE
DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED W/SPECIAL CAUTN (ING 15)

Fire Fighting

Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCLUDE
FLUORIDES, CHLORIDES & PHOSGENE . OTHER BURNING MATLS CAN CAUSE
CMPD TO BURN. EXTING, WATER/FOG SHOULD BE USED TO(SUPDAT)

Accidental Release

Spill Release Procedures:VENTILATE AREA-ESPECIALLY LOW PLACES WHERE
HEAVY VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES. USE NIOSH/MSHA
APPROVED SELF-CONTAINED BREATHING APPARATUS (SCBA) FOR LARGE SPILLS
OR RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES,FLUORIDES OR
PHOSGENE .

Exposure Controls

Respiratory Protection:NO RESPIRATORY PROTECTION IS REQUIRED.
NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS (SCBA) IS
REQUIRED IF A LARGE RELEASE OCCURS.
Ventilation:NORMAL VENT FOR STD PROC IS GEN ADEQ. LOC EXHST SHOULD BE
USED WHEN LG AMTS ARE RELSD. MECH VENT SHOULD BE USED (ING 16)
Protective Gloves:LINED BUTYL GLOVES WHEN HNDLG LIQ.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER WHICH
MEET ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
BP:-41.4F(-40.8C) (@1 ATM F). VP:151 (PSIA @ 25C). EXPLO HAZS:COOL
CNTNRS. DECOMP MAY OCCUR. HAZ DECOMP PRODS:ACIDS, & POSS CARBONYL
HALIDES. CHLORIDES, FLUORIDES & PHOSGENE . EFTS OF OVEREXP:@ CONC
OF 50,000 PPM (V/V). IN SAME STUDIES, NO CARCIN EFTS WERE SEEN IN
EITHER SPECIES AT CONCS OF 10,000/1000 PPM(ING 2)

Chemical Properties

Boiling Pt:B.P. Text:SUPP DATA
Vapor Pres:SUPP DATA
Vapor Density:3.03 @ 25C
Spec Gravity:1.194(G/CC@25C)
Evaporation Rate & Reference:NOT AVAILABLE
Solubility in Water:0.30W/WT @ 1ATM@25C
Appearance and Odor:CLEAR, LIQUIFIED GAS WITH A SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100.0

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:CAN BE DECOMPOSED BY HIGH TEMPS (OPEN
FLAMES, GLOWING METAL SURFS, ETC. FORMING HYDROCHLORIC &
HYDROFLUORIC (SUPP DATA)

Disposal

Waste Disposal Methods:RECLAIM BY DISTILLATION. COMPLY WITH FEDERAL,
STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.